Air Conditioner Test Rig Manufacturer,Supplier and Exporter in India
Product Code : EL-ME-10650
Quick Answer: This air conditioner test rig is a teaching set-up with a hermetically sealed single-phase compressor, an air-cooled finned-tube condenser and a 1 TR finned copper-tube evaporator coil. It is used to find the coefficient of performance, refrigerating effect and sensible heat factor of an air-conditioning unit.
Last updated: October 2026
Key Features
- Hermetically sealed compressor for single-phase 220/230 V supply
- Air-cooled condenser of finned-tube type
- Evaporator cooling coil of fins and copper tube, 1 TR capacity
- 5 PT100 temperature sensors at the condenser and evaporator inlets and outlets and at the blower
- High- and low-pressure gauges and a rotameter for liquid refrigerant flow
- Control panel with main switch, wattmeter and digital ammeter, on a sturdy frame
Technical Specifications
| Specification | Value |
|---|---|
| Evaporator capacity | 1 TR |
| Compressor | Hermetically sealed, single phase 220/230 V |
| Condenser | Air cooled, finned tube |
| Pressure gauges | 1 high pressure, 1 low pressure |
| Temperature sensors | 5 x PT100 with multi-channel digital indicator |
| Power supply | Single phase 220 V, 50 Hz AC |
About This Product
Students run the unit and read pressures, temperatures, refrigerant flow and electrical input to work out how an air-conditioning cycle performs. Typical experiments are calculating the coefficient of performance, finding the refrigerating effect and horsepower, and calculating the sensible heat factor of the air. An operation and maintenance manual is supplied with the rig. School Equipment India supplies the air conditioner test rig from Ambala and can export it to South Korea, Djibouti, Chad, Vanuatu and Belarus.
Frequently Asked Questions
Which experiments can be done on the air conditioner test rig?
The rig is used to calculate the coefficient of performance (COP), determine the refrigerating effect and horsepower of the unit, and calculate the sensible heat factor of air.
Where are the temperature sensors fitted?
Five PT100 sensors are placed at the condenser input and output, the evaporator input and output, and the blower.