Portable Patient Monitor Manufacturer,Supplier and Exporter in India

Product Code : EL-MD-10582
School Equipment India is a Leading Portable Patient Monitor Manufacturer,and suppliers in India, Portable Patient Monitor Manufacturer,and suppliers in South Africa, Portable Patient Monitor Algeria (Algiers), Portable Patient Monitor Angola (Luanda), Portable Patient Monitor Argentina (Buenos Aires), Portable Patient Monitor Armenia (Yerevan), Portable Patient Monitor Australia (Canberra), Portable Patient Monitor Austria (Vienna), Bahrain (Manama), Bangladesh (Dhaka), Bhutan (Thimphu), Bolivia (Sucre), Botswana (Gaborone), Brazil (Brasília), Brunei (Bandar Seri Begawan), Montenegro (Podgorica), Morocco (Rabat), Mozambique (Maputo), Myanmar (Naypyidaw), Namibia (Windhoek), Nepal (Kathmandu), New Zealand (Wellington), Nigeria (Abuja), Oman (Muscat), Palestine (Ramallah), Panama (Panama City), Papua New Guinea (Port Moresby), Paraguay (Asunción), Peru (Lima), Philippines (Manila)¸ Portugal (Lisbon), Qatar (Doha), Rwanda (Kigali), Saudi Arabia (Riyadh), Senegal (Dakar), Serbia (Belgrade), Sierra Leone (Freetown), Slovakia (Bratislava), South Africa (Cape Town) (Pretoria) (Bloemfontein), South Sudan (Juba), Spain (Madrid), Sri Lanka (Sri Jayawardenepura Kotte) (Colombo), Sudan (Khartoum), Syria (Damascus), Tanzania (Dodoma), Thailand (Bangkok), Togo (Lomé), Tonga (Nuku'alofa), Trinidad and Tobago (Port of Spain), Tunisia (Tunis), Turkey (Ankara), Turkmenistan (Ashgabat), Uganda (Kampala), United Arab Emirates (Abu Dhabi), United Kingdom (London), United States (Washington, D.C.).

Respiratory rate (RR):
RR range 0 – 120 adult, 0 – 150 paediatric/neonatal
Resolution: 1 rpm
Accuracy: ± 2 rpm or ± 2% in the range 7 – 150 rpm, whichever is greater

Temperature:
Range 0 – 50 ºC
Resolution ± 0.1 ºC
Accuracy ± 0.1 ºC

NIBP:
Oscillometric step deflation
Adjustable inflating pressure
Systolic, diastolic and mean pressure measurement
Measurement overall ranges: 10 – 270 adult, 10 – 200 paediatric, 10 – 135 neonatal
Resolution: 1 mmHg

SpO2:
Range 0 – 100%
Resolution 1%, accuracy ± 2% in the range 70 – 100 %
Heart rate detection 25 – 250 bpm, accuracy ± 3 bpm or ± 2%, whichever is greater

ECG and HR:
3-leads ECG, I-II-III selection 
Waveform visualization
Gain 1.25, 2.5, 5, 10, 20, 40 mm/mV and Auto
Sweep speed 6.25, 12.5, 25 and 50 mm/s
Accuracy ± 1 bpm or ± 1%, whichever is greater
S-T detection, arrhythmia analysis
Standardizing marker -1 to 1 mV or -2 to 2 mV 
HR 15 – 300 bpm for adult and 15 – 350 bpm for paediatric/neonatal

Adjustable signal amplitude and sensitivity
TFT color display > 10.4 inches
Multi-waveform and parameters visualization, at least 4 channels
Defibrillator sync and protection
Pacemaker detection/rejection

Data and network interface
Suitable for standard bed/wall rail and pole stand mount
Robust design for use in demanding environment
Automatic self-test and continuous system monitoring
Built-in rechargeable battery, autonomy > 3.5 hours
Power requirements: 100 - 220 V / 50 Hz
Patient information and trend internal database
Trend display > 120 hours at 1 min resolution
Audio-visual alarms and silencing feature for all monitored parameters
Display reports alarms, system errors, leads and sensors failure and AC/battery status
Soft touch keys, durable and easy to clean surface, resistant to hospital-grade cleaning products
Automatic switch to battery in case of power failure, automatic recharge on connection to mains


   